Page 855 - Demo
P. 855


                                    823TECHNICAL DATADATA SUBJECT TO CHANGE WITHOUT NOTICE.Allen Bradley bulletin 1494V disconnect switchesENCLOSURE DEPTH HEIGHT HEIGHTTYPE NUMBERAMP RATING8\ 12%u201d OR 16%u201d 60%u201d 72%u201d 72%u201d 84%u201d 90%u201dF K F K F K F K F K F K F KWire bend space above disconnect switch for catalog number*These switches will only fit enclosures  5100 ESYB603712, 5100 ESAB603712, 5412 ESAB603712, 5412 ESSAB603712  5500 ESYB603712, 5500 ESSYB603712%u201cK%u201d is the wire bending space %u201cF%u201d is the distance from top of cabinet to switch mounting hole  Note: All dimensions in inches 5100 ESY & ESA, 5412 ESA & ESSA 5500 ESY, ESSY, UFD, UFDSS, UCD & UCDSS, 9500 UXD, UXDSS FKWIRINGSPACEDISCONNECTAREAFKWIRINGSPACEDISCONNECTAREA6500 MXUDS30 30A 8.63 6.57 11.63 9.57 7.88 5.82 13.88 11.82 11.88 9.82 17.88 15.82 20.88 18.82DS60 60A 8.63 5.81 11.63 8.81 7.88 5.06 13.88 11.06 11.88 9.06 17.88 15.06 20.88 18.06DS100 100A 8.63 5.55 11.63 8.55 7.88 4.89 13.88 10.89 11.88 8.89 17.88 14.89 20.88 17.89DS200 200A 8.63 %u2014 11.63 8.10 7.88 %u2014 13.88 10.35 11.88 8.35 17.88 14.35 20.88 17.35DS400* 400A 8.63 %u2014 11.63 %u2014 7.88 %u2014 13.88 %u2014 11.88 %u2014 17.88 10.11 20.88 13.11DS600* 600A 8.63 %u2014 11.63 %u2014 7.88 %u2014 13.88 %u2014 11.88 %u2014 17.88 10.11 20.88 13.11367348344330222222K6500 MXUAllen Bradley bulletin 1494V operators for circuit breakersF K F K F K F K F K F K F KWire bend space above disconnect switch for catalog numberM40 15A-150A 8.63 7.95 11.63 10.95 7.88 7.25 13.88 13.25 11.88 11.25 17.88 17.25 20.88 20.25M50 70A-250A 8.63 %u2014 11.63 10.55 7.88 6.80 13.88 12.80 11.88 10.80 17.88 16.80 20.88 19.80M60 100A-400A 8.63 %u2014 11.63 10.35 7.88 %u2014 13.88 12.60 11.88 10.60 17.88 16.60 20.88 19.60404392392KSchneider Square D class 9422 variable depth operators - circuit breakersF K F K F K F K F K F K F KWire bend space above disconnect switch for catalog numberRG-1 75A 8.63 7.43 11.63 10.43 7.88 6.68 13.88 12.68 11.88 10.68 17.88 16.88 20.88 19.68RG-1 100A 8.63 7.43 11.63 10.43 7.88 6.68 13.88 12.68 11.88 10.68 17.88 16.68 20.88 19.68RN-1 100A 8.63 7.63 11.63 10.63 7.88 6.88 13.88 12.88 11.88 10.88 17.88 16.88 20.88 19.88RP-1 250A 8.63 8.30 11.63 11.30 7.88 7.55 13.88 13.55 11.88 11.55 17.88 17.55 20.88 20.55RR-1 400A 8.63 %u2014 11.63 7.00 7.88 %u2014 13.88 9.25 11.88 %u2014 17.88 13.25 20.88 16.25RT-1 800A 8.63 %u2014 11.63 %u2014 7.88 %u2014 13.88 %u2014 11.88 %u2014 17.88 13.10 20.88 16.10RT-1 1000A 8.63 %u2014 11.63 %u2014 7.88 %u2014 13.88 %u2014 11.88 %u2014 17.88 13.10 20.88 16.10389389389411301298298K%u201cK%u201d is the wire bending space %u201cF%u201d is the distance from top of cabinet to switch mounting hole  Note: All dimensions in millimeters Reference for the tables of wiring space above main disonnect deviceHEIGHT F=420mm6500 MXUHEIGHT F=420mm6500 MXUHEIGHT F=420mm5100 ESY & ESA 5412 ESA & ESSA 5500 ESY & ESSY5500 UFD & UFDSS 5500 UCD & UCDSS9500 UXD 9500 UXDSS5100 ESY & ESA 5412 ESA & ESSA 5500 ESY & ESSY5500 UFD & UFDSS 5500 UCD & UCDSS9500 UXD 9500 UXDSS5100 ESY & ESA 5412 ESA & ESSA 5500 ESY & ESSY5500 UFD & UFDSS 5500 UCD & UCDSS9500 UXD 9500 UXDSSENCLOSURE DEPTH HEIGHT HEIGHTTYPE NUMBERAMP RATING8\ 12%u201d OR 16%u201d 60%u201d 72%u201d 72%u201d 84%u201d 90%u201dENCLOSURE DEPTH HEIGHT HEIGHTTYPE NUMBERAMP RATING8\ 12%u201d OR 16%u201d 60%u201d 72%u201d 72%u201d 84%u201d 90%u201dTABLES OF WIRING SPACE ABOVE MAIN DISCONNECTING DEVICE
                                
   849   850   851   852   853   854   855   856   857   858   859